• Humidity Sensor Hr002 for Air Control System
  • Humidity Sensor Hr002 for Air Control System
  • Humidity Sensor Hr002 for Air Control System
  • Humidity Sensor Hr002 for Air Control System
  • Humidity Sensor Hr002 for Air Control System

Humidity Sensor Hr002 for Air Control System

Installation Type: Duct Type
Sensing Type: Thermocouple
Contact: Contactless
Output Signal Type: Digital Type
Production Process: Integration
Material: Carbon Humidity
Samples:
US$ 0.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
HR002
Measuring Medium
Humidity
IP Rating
IP20
Certification
CE
Customized
Customized
Transport Package
1000PCS in One Pack
Specification
100000pcs in one carton
Trademark
HW
Origin
Guangdong, China
HS Code
8421991000
Production Capacity
100000PCS/Week

Product Description

1. Product introduction:

The product is called resistance type polymer humidity sensor (HR002) and it is a new type of humidity sensor. It has the characteristics of wide sensing range, fast response, high sensitivity, good water resistance, stable and reliable performance, and good consistency.


2.Electrical performance:
1. Rated voltage: 1.5V AC (MAX, sine wave);
2. Rated power: 0.2mW (MAX, sine wave);
3. operating frequency: 50Hz-2000Hz;
4. working temperature: 0 °C -60 °C;
5. working humidity: 20% - 95% RH;
6. Temperature characteristics: ≤0.5%RH/°C
7. hysteresis hysteresis: ≤ 2% RH;
8. Response time: moisture absorption, ≤15S; dehumidification ≤25S;
9. Stability: ≤ 2% RH/year;
10. Humidity detection accuracy: ≤±5%RH;
11. Relative humidity impedance characteristics: (25°C, 1KHZ, AC1V, sine wave)

 

3.Standard verification conditions:

1.In the atmosphere, the temperature is 25°C, the measured frequency is 1KHZ, and the measured voltage is IVAC (sine wave);
2.Make sure to use AC bridge (LCR) when testing, and do not use DC power supply;
3.Use split-type humidity generator (HX-1 type);
4.Measurement line: 1-core shielded wire.
5.Avoid hard objects or fingers touching the surface of components to avoid scratching or staining the wet film;
6.Avoid testing under salt spray, corrosive gases, strong acids, strong bases, organic solvents, alcohol, acetone, etc.
7.Welding conditions (180°C, 3S) For welding, use a low-temperature soldering iron or use tweezers for protection.
8.Recommended Storage Conditions: Temperature 10°C-40°C, Humidity: 20%RH-90%RH.


The specification value is based on the 60%RH humidity change amount; after each test is completed, it should be placed in the normal air of normal temperature and humidity for 24 hours and tested after recovery. The test data are listed in the table.   
Humidity Sensor Hr002 for Air Control System

1-Exported feet  2-Substrates  3-Carbon Electrodes  4-Sensitive Wet Film
Figure 1 (1008) dimensions



Table 1 Humidity Impedance Characteristics Table at 0°C to 60°C (31KΩ)
   0ºC  5ºC 10ºC  15ºC  20ºC  25ºC  30ºC  35ºC  40ºC  45ºC  50ºC  55ºC  60ºC 
20%RH       2290 1759 1351 1027 780 591 448 359 288 227
25%RH   2100 1620 1250 935 700 539 415 328 260 218 183 149
30%RH 1543 1175 874 650 498 382 302 238 198 165 143 124 94
35%RH 832 612 465 353 277 217 180 150 128 109 90.4 75 61.8
40%RH 443 335 260 202 165 135 114 97 81.2 68 59.5 52 43.6
45%RH 248 190 153 123 105 90 76.5 65 55.6 47.5 41.9 37 31.3
50%RH 146 115 98.9 85 72 61 52.4 45 39.1 34 30.1 26.7 22.7
55%RH 94 80 68.1 58 49.9 43 37.1 32 28 24.5 21.9 19.5 15.6
60%RH 64.3 56 48.2 41.5 35.9 31 26.6 22.9 20.2 17.8 15 12.6 10
65%RH 45.9 41 35.1 30 25.9 22.3 19.2 16.5 13.8 11.6 9.6 7.9 6.45
70%RH 33.4 30 25.6 21.9 18.7 15.9 13.1 10.8 9 7.5 6.2 5.13 4.29
75%RH 24.4 21.5 18.3 15.6 12.8 10.5 8.69 7.2 5.95 4.92 4.13 3.46 2.84
80%RH 17.4 15.3 12.6 10.3 8.5 7.03 5.8 4.78 3.98 3.31 2.73 2.25 1.88
85%RH 12 10.2 8.4 6.91 5.67 4.65 3.86 3.2 2.65 2.19 1.81 1.49 1.24
90%RH 7.9 6.87 5.6 4.56 3.77 3.11 2.56 2.11 1.74 1.44 1.19 0.99 0.82

Figure 2 humidity impedance characteristics (31KΩ)
Table 2 0°C to 60°C (23KΩ) Humidity Impedance Characteristics Data Sheet
   0ºC  5ºC 10ºC  15ºC  20ºC  25ºC  30ºC  35ºC  40ºC  45ºC  50ºC  55ºC  60ºC 
20%RH       1699.0  1305.1  1002.4  762.0  578.7  438.5  332.4  266.4  213.7  168.4 
25%RH   1558.1  1201.9  927.4  693.7  519.4  399.9  307.9  243.4  192.9  161.7  135.8  110.5 
30%RH 1144.8  871.8  648.5  482.3  369.5  283.4  224.1  176.6  146.9  122.4  106.1  92.0  69.7 
35%RH 617.3  454.1  345.0  261.9  205.5  161.0  133.5  111.3  95.0  80.9  67.1  55.6  45.9 
40%RH 328.7  248.5  192.9  149.9  122.4  100.2  84.6  72.0  60.2  50.5  44.1  38.6  32.3 
45%RH 184.0  141.0  113.5  91.3  77.9  66.8  56.8  48.2  41.3  35.2  31.1  27.5  23.2 
50%RH 108.3  85.3  73.4  63.1  53.4  45.3  38.9  33.4  29.0  25.2  22.3  19.8  16.8 
55%RH 69.7  59.4  50.5  43.0  37.0  31.9  27.5  23.7  20.8  18.2  16.2  14.5  11.6 
60%RH 47.7  41.5  35.8  30.8  26.6  23.0  19.7  17.0  15.0  13.2  11.1  9.3  7.4 
65%RH 34.1  30.4  26.0  22.3  19.2  16.5  14.2  12.2  10.2  8.6  7.1  5.9  4.8 
70%RH 24.8  22.3  19.0  16.2  13.9  11.8  9.7  8.0  6.7  5.6  4.6  3.8  3.2 
75%RH 18.1  16.0  13.6  11.6  9.5  7.8  6.4  5.3  4.4  3.7  3.1  2.6  2.1 
80%RH 12.9  11.4  9.3  7.6  6.3  5.2  4.3  3.5  3.0  2.5  2.0  1.7  1.4 
85%RH 8.9  7.6  6.2  5.1  4.2  3.5  2.9  2.4  2.0  1.6  1.3  1.1  0.9 
90%RH 5.9  5.1  4.2  3.4  2.8  2.3  1.9  1.6  1.3  1.1  0.9  0.7  0.6 


Humidity Sensor Hr002 for Air Control System
Figure 3 Humidity Impedance Characteristic Diagram (23KΩ)
Humidity Sensor Hr002 for Air Control System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.