Customization: | Available |
---|---|
Type: | Probe |
Usage: | Anti-theft, Temperature, LED Light |
Still deciding? Get samples of US$ 0.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITEM | CONDITION | RATING |
6.1 Signal Output |
Black Body temperature: 420K
|
>6500mVp-p |
6.2 Noise Output |
|
< 140mVp-p |
6.3 Balance output |
Black Body temperature: 420K
S1 = A+C (Vp-p) S1 = A+C Element sensitivity (Vp-p) S2 = B+D (Vp-p) S2 = B +DElement sensitivity (Vp-p) |
|S1-S2|/(S1+S2) ×100%≤15% |
6.4 Operating Voltage |
Single power supply RS=47KΩ | 2~15V |
6.5 Source Voltage |
VD=5V,RS=47KΩ |
0.4~1.0V |
6.6 Circuit Configuration |
See Fig.4 | |
6.7 Warm-up Time |
After it conneted, it with the measurement amplifier for Fig.3 description that turns on the power supply beforehand, the amplification output is time until stabilizing. | Max: 25 Sec |
ITEM | RATING |
7.1 |
115 degrees from center of Element on Axis X. |
Field of View | 110 degrees from center of Element on Axis Y. |
See Fig 5 | |
7.2 Response wavelength band |
Filter substrate:Silicon Cut on wavelength:5.5±0.5μm Transmission:7~14μm ≥75% |
7.3 Transmission Characteristics of filter |
See Fig 6 |
ITEM | RATING |
8.1 Operating Tmeperature |
-30~70 ºC |
8.2 Storage Temperatur |
-40~80 ººC |
8.3 Relative Humidity |
The sensor shall operate without increase in Noise Output when exposed to 90 to 95% RH at 30ºC continuously |
8.4 Hermetic Seal |
No bubbles visible in the 125±5ºC fluorocarbon bath(FC-40) for 20sec |
8.5 Reliability Test | Specified in Appendix1( page13~14) |