Hw-F335 Fire Alarm with RS-485 Protocol Supported

Product Details
Customization: Available
Function Type: Flame Sensor Alarm
Detection Type: Flame Sensor Alarm
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Trading Company
Secured Trading Service
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2004-08-19
Number of Employees
17
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
  • Hw-F335 Fire Alarm with RS-485 Protocol Supported
Find Similar Products

Basic Info.

Model NO.
HW-F335
Output Signal Type
Analog Type
Production Process
Integration
Material
Plastic
IP Rating
IP65
Certification
RoHS
Customized
Customized
Model
Hw-F335
Power Supply
12V
Sensing Distance
1~30m
Fire Alarm Threshold
300*300mm
Fire Alarm Sending Delay Time
5s~10s
Sensing Angle
10-110°
Sensor Probe Wavelength
380-750nm
Product Dimensions
54*45*25mm
Operating Temperature
-20----+70
Transport Package
Plastic
Specification
55 x 55 x 70mm
Origin
China

Packaging & Delivery

Package Size
18.00cm * 18.00cm * 8.00cm
Package Gross Weight
0.800kg

Product Description

I. Fire Alarm User Manual
The HW-F335 is a civilian fire alarm device. It uses a three-band sensing method combining infrared, ultraviolet, and thermal radiation, and employs the Curie temperature of lithium tantalum crystal material. It is suitable for flame temperatures ranging from 250-4000ºC and provides a clear high-contrast polarity change for fire early warning. The detector has stable performance and can quickly detect and trigger an alarm within 5-10 seconds when a fire occurs. The product can be set up by scanning a QR code with a mobile phone and is used for various open flame detection fire early warning applications, including fire alarms, security alarms, industrial plants, mining areas, chemical combustible material alarms, residential homes, charging piles, gas stations, chargers, equipment, and more.
II.  Setup Instructions
1.Power supply via RS-8 twisted-pair cable, ceiling-mounted detection method in fire escape passages.
2.Multi-channel output: 485A · 485B · high-level fire alarm signal · dry contact relay output for fire alarm.
3.Enclosed in a metal housing.
4.Highly sensitive outdoor fire detection, open for secondary development.
5.Wide range of applications, especially suitable for outdoor scenarios.
6.Immunity to electromagnetic radiation, sunlight, and background thermal radiation.
7.Passive operation, low power consumption, multi-layer protection, and ultra-long service life design.

III. Alarm threshold: Refer to the chart:
Model HW-F335   485 Flame Alarm
Power supply 12v/500mA   12v Relay
Work indicator light Blue: The indicator light shows normal operation. Red: Alarm indicator light.
Power consumption <3w
Sensing distance 1-30m The larger the fire, the faster the detection
Fire alarm threshold 300mmx300mm Area fire flame, size alarm threshold
Sensor 39----43----51 Three-band flame detection
Output 3-channel signal 458A - 485B Relay switch output high-level output
Output port 1-2.54-4 2-2.54-4 PCB silkscreen
Network cable RS8 core network cable, 200mm in length.
Blackbody threshold 500k 1HZ 0.3-3BPS default500K
Fire alarm sending time 5s-10s Fire alarm duration: 3-5 seconds Repeatable triggering
Sensing angle 10-110°   Window angle
Sensor probe wavelength 380-750nm    
Metal casing accessories host x 1pcs  Lower casing x 1pcs power supply x 1pcs
  upper casing x 1pcs Screw decorative ringx 1pcs Screw packagex 1pcs
Module size 54mmx45mmx25mm   Single module size
Operating temperature -20----+70    


IV. Output port definition
Line number Color definition
1 Orange-white VCC
2 Orange GND
3 Green-white 485A+
4 Blue Relay K
5 Blue-white RelayON
6 Green 485B-
7 Brown-white Relay NC
8 Brown Fire alarm high level OUT
V. Detection Range Schematic and Response Time Definitions
Hw-F335 Fire Alarm with RS-485 Protocol Supported


The fire alarm detection time is as follows: when the triggering conditions are met, the fire will continue to output a trigger signal as long as the fire is extinguished, indicated by a constantly lit red LED. When the flame disappears, the flame sensor source will reset in approximately 5 seconds, returning to sentinel detection mode. This detection time is determined when a fire occurs.
1. Avoid installation in areas with heavy steam/oil fume, such as kitchens and bathrooms, and keep away from air conditioning vents and dust accumulation areas to prevent false alarms.
2. Clean the optical sensor quarterly with a soft brush to prevent dust from obstructing detection accuracy.
3. Monthly check the audible and visual alarms and power connection by pressing the test button to ensure timely response in case of fire.

Hw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol SupportedHw-F335 Fire Alarm with RS-485 Protocol Supported
 