Hw-Hy004 Flame Alarm Sensor Module--Three Probe

Product Details
Customization: Available
Installation Type: Wall-Mounted Type
Sensing Type: Thermocouple
Still deciding? Get samples of US$ 43/Piece
Request Sample
Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
17
Year of Establishment
2004-08-19
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
  • Hw-Hy004 Flame Alarm Sensor Module--Three Probe
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
HW-HY004
Contact
Contactless
Output Signal Type
Analog Type
Production Process
Integration
Material
Dewpoint Lithium Chloride
Measuring Medium
Temperature
IP Rating
IP68
Certification
RoHS
Customized
Customized
Model
Hw-Hy004 Flame Alarm Module
Vcc
3.3V~12V
out-Siginal
Ttl Signal
Induction Method
Passive Flame Thermal Radiation Detection
Induction Angle
10-110°
Induction Time
Continuous High Level When There Is Fire
Induction Distance
1~50m
Transport Package
Standard Package
Specification
1pcs
Trademark
HW
Origin
China
Production Capacity
1000/Week

Product Description

Product Description

 


1.Product Overview
HW-HY004 is the company's latest single-board thermal radiation flame alarm sensor module. The passive single sensor detection adopts: thermal radiation induction judgment method, using the Curie temperature of lithium carbonate crystal material, for flame temperature 250-4000ºC and above, wavelength 380-750nm flame accurate detection and warning. The relative dielectric constant is small, and within a wide range of room temperature, for fire warning, there can be obvious temperature difference high contrast polarity changes, the detector performance is stable, when a fire occurs, it can quickly capture the response to trigger an alarm within 1 to 2 seconds, and is used for various types of open flame induction fire warnings: fire warning, security warning, industrial plants, mining areas, chemical combustible alarms, family residences, charging piles, gas stations, chargers, equipment and machinery, etc.
2.Operational Principle
HW-HY004 is a flame detector using lithium carbonate crystal composite materials. It uses filters to test spectra of different bands to detect visible or invisible light radiation generated when materials burn, while generating smoke and releasing heat. It uses the light characteristics of flames for shorter ultraviolet bands and longer infrared bands. When different materials burn, the red and ultraviolet spectra they emit are different. The environmental spectrum is distinguished from the flame spectrum, thereby causing the sensor electric field phase change and outputting a warning signal.
3.Product Features
HW-HY004 ternary sensor captures signals with wide coverage, high consistency, low power consumption, and meets the certification requirements of ROHS.CE.KC.UL, etc. It also has strong anti-interference ability and is not affected by ambient temperature, humidity, airflow, dust, noise, brightness, etc. Special anti-interference ability. It can better adapt to the application occasions of the secondary development of most smart products. When this product is used indoors, the sensing effect is better; when used outdoors, due to the influence of the environment, the sensing distance is slightly shortened or the sensitivity is slightly weaker. This is a normal phenomenon, and users do not need to question the product. This product is mostly used in macro scenes.
4.Induction Time
   Fire warning capture time, when the trigger condition is reached, the trigger signal will be output continuously, and the LED indicator will be always on. When the flame disappears, the flame sensor source will reset within 3-5 seconds and resume detection mode. The sensing time is determined by the occurrence of the fire.
Product Parameters

 


5.Parameter Specifications
Model HY004 Flame alarm module Single probe short distance 43
VCC Min:3.3V Middle value: 5v Maximum value: 12v (withstand voltage 3.3v-18v-300mA)
V/A <30mA  
OUT-Siginal TTL signal AD/SLK DIO serial port signal
Induction method Passive flame thermal radiation detection
Induction Distance 1-50m Determined by the heat source coefficient Thermal radiation proportional coefficient
Blackbody threshold 500k 1HZ 0.3-3BPS Default 500K
Induction time Continuous high level when there is fire Reset within 30 seconds after fire extinguishing  
Induction angle 10-110°   Window angle
Sensor wavelength 380-750nm   Flame thermal radiation wavelength (refer to the following text)
Spectral wavelength of filter (refer to the following text)   Chemical combustible spectrum(refer to the following text)
Size 41.5mm x26.7x12mm square  
Port Data output 1.25mm-6pin Port 1.25mm-3pin  
working temperature -20----+70    

6.Product inspection wiring diagram and CAD diagram
Hw-Hy004 Flame Alarm Sensor Module--Three Probe

As shown in the figure, VIN can supply DC5V, and various identification data interfaces are for the microcontroller to collect signals.
Port J1: The output port is the flame output port and the positive and negative input of the power supply.
Port J2: External serial port data output.
Port J3: Software editing and burning port.
Button SW: Data reset switch.
Later, the J1 port can be used to output a high-level signal. If there is a fire in the detection area, the LED will light up red to alarm, and the LED will flash blue, which is the sentry mode. The red LED will continuously trigger the signal: connect the security fire warning circuit, trigger circuit-MOS tube-thyristor-relay-MCU to collect signals to alarm the occurrence of fire, etc.
CAD Dimensions:
Hw-Hy004 Flame Alarm Sensor Module--Three Probe