Hw-F210-E Ceiling Mounted Fire Alarm

Product Details
Customization: Available
Function Type: Flame Sensor Alarm
Detection Type: Flame Sensor Alarm
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Trading Company
Secured Trading Service
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2004-08-19
Number of Employees
17
  • Hw-F210-E Ceiling Mounted Fire Alarm
  • Hw-F210-E Ceiling Mounted Fire Alarm
  • Hw-F210-E Ceiling Mounted Fire Alarm
  • Hw-F210-E Ceiling Mounted Fire Alarm
  • Hw-F210-E Ceiling Mounted Fire Alarm
  • Hw-F210-E Ceiling Mounted Fire Alarm
Find Similar Products

Basic Info.

Model NO.
HW-F210-E
Output Signal Type
Analog Type
Production Process
Integration
Material
Plastic
IP Rating
IP65
Certification
RoHS
Customized
Customized
Model
Hw-F210-E Ceiling-Mounted Fire Alarm
Power Supply
85V-220V
Sensing Distance
1~30m
Fire Alarm Threshold
300*300mm
Fire Alarm Sending Delay Time
5s~10s
Sensing Angle
10-110°
Sensor Probe Wavelength
380-750nm
Product Dimensions
100*100*35mm
Operating Temperature
-20----+70
Transport Package
Plastic
Specification
55 x 55 x 70mm
Origin
China

Packaging & Delivery

Package Size
18.00cm * 18.00cm * 8.00cm
Package Gross Weight
0.800kg

Product Description

I. Fire Alarm User Manual
The HW-F210-E is an English-language civilian fire alarm. It uses a dual-band infrared and thermal radiation sensing method, employing lithium thallium crystal material with a Curie temperature range of 250-4000ºC. For fire early warning, it exhibits a clear high-contrast polarity change due to temperature differences. The detector is stable and can quickly detect and trigger an alarm within 10 seconds of a fire. The product can be set up by scanning a QR code with a mobile phone. It is suitable for various open flame detection fire early warning applications: fire alarm, security alarm, industrial plants, mining areas, chemical combustible material alarm, residential homes, charging piles, gas stations, chargers, equipment, etc.
II. Setup Instructions
1. Use a 220V lead wire for power supply and wiring. It is installed indoors in a fire escape corridor using a ceiling-mounted detection method.
2. Wait for the fire alarm to self-test and power on: Welcome to Haiwang Fire Alarm. Please place this product according to the instructions. This product is for fire detection; please install it ceiling-mounted with a downward view.
3. The product detects a fire: Fire alarm! Fire alarm! Please have the relevant personnel handle this as soon as possible;
4. Dual-speaker voice broadcast, louder sound;
5. Enters sentry mode after the power-on voice message ends.
Model F210-E   Flame alarm
Power supply 85v-250v   220v
Work indicator light Blue: The indicator light shows normal operation. Red: Alarm indicator light.
Power consumption <3w
Sensing distance 1-30m The larger the fire, the faster the detection
Fire alarm threshold 300mmx300mm Area fire flame, size alarm threshold
Sensor 43----51 Dual-band flame detection
Output signal WeChat pop-up Telephone dialing Phone text messages
network 5G/4G
Supported by operators China Telecom China Mobile China Unicom
Blackbody threshold 500k 1HZ 0.3-3BPS default500K
Fire alarm sending time 5s-10s Fire alarm held for 30s Repeatable triggering
Sensing angle 10-110°   Window angle
Sensor probe wavelength 380-750nm    
Metal casing accessories host x 1pcs Fixed plate x 1pcs  
Product Dimensions Length 100mm x width 100mm thickness 35mm  
Operating temperature -20----+70    

IV. Sensing Time:
After the power-on voice announcement ends, the blue breathing light indicates Sentinel mode, which is the fire alarm detection time. When the trigger condition is met, the system will continuously output a trigger signal as long as the fire persists, indicated by a constantly lit red LED. When the flame disappears, the flame sensor source will reset in approximately 30 seconds, returning to Sentinel detection mode. This sensing time is determined by the occurrence of a fire.

The fire alarm detection time is determined by the fire alarm's detection time. When the triggering conditions are met, the fire will continue to output a trigger signal as long as the fire is extinguished. The red LED indicator will remain constantly lit. When the flames disappear, the flame sensor source will reset approximately 30 seconds later, returning to sentinel detection mode. This sensing time is determined when a fire occurs.


Precautions:
1. Avoid installation in areas with heavy steam/grease buildup, such as kitchens and bathrooms, and keep away from air conditioner vents and dust accumulation areas to prevent false alarms.
2. Clean the optical sensor quarterly with a soft brush to prevent dust from obstructing detection accuracy.
Monthly check the audible and visual alarms and power connection using the test button to ensure timely response in case of fire.

V. Alarm Thresholds:
Refer to the chart.