Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector

Product Details
Customization: Available
LED Light Source: Small Straw Hat
Emitting Color: Full Color Single Point of Control
Still deciding? Get samples of US$ 1/Piece
Request Sample
Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
17
Year of Establishment
2004-08-19
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
  • Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Find Similar Products

Basic Info.

Model NO.
HW-SR501
1 LED Power
0.3-0.5W
Power
3W
LED Chips
CREE
IP Rating
IP68
Waterproof
Not Waterproof
Products
Hw-Sr501 PIR Sensor Module
Transport Package
by Tray
Trademark
HW
Origin
China
HS Code
8517709000
Production Capacity
50000/Week

Product Description

HW-SR501 PIR Sensor Module

Specification
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector

Based on infrared technology automatic control products, HC-SR501 has high sensitivity and reliability, and is widely used in various types of automatic induction appliances, such as automatic doors, automatic washing mobile phones, automatic liquid droppers, sensor flushers, various types of smart toys, energy-saving lamps. , Automatic body-sensing night light and other induction electrical equipment.
     
 Features

1 Fully automatic sensing: When a person enters its sensing range, it outputs a high level. When the person leaves the sensing range, it automatically delays and turns off the high level and outputs a low level.
2 Photosensitive control, no induction in daytime or strong light, night induction. (Default is no photosensitive control)
3 two trigger modes (default repeatable trigger)
   a. Non-repeatable triggering mode: After the sensor output is high, once the delay period ends, the output will automatically change from high level to low level;
   b. Repeatable triggering mode: after the sensor output is high, during the delay time period, if there is activity of the human body in its sensing range, the output will remain high until the person will delay and then leave high power. Level changes to low level (the sensing module automatically delays a delay period after detecting each activity of the human body, and the time of the last activity is the starting point of the delay time).

 Technical Parameters
 
Product Model HC-SR501 Batch can be customized
The level of the output is not an absolute value. The change of the ambient temperature will have a slight influence on it, and an error value of about ±0.5V may occur.
Modules are reserved CDS photoresistor interface for light control functions;
Other customized items may add additional costs. It is recommended to maintain regular parameters. Please discuss and communicate with relevant staff for specific matters.
Working Voltage DC4.8V-20V can be customized
Static Power <50 uA;  
Level Output Induction3.3V
No induction0V
can be customized
Delay Time 0.5-200S Available fixed resistance
Block Time 2.5s can be customized
Trigger Mode  L can not be repeated, H can be repeated default value H  
Induction Distance 5,8,10m can be customized
Induction Angle Range 100° can be customized
Working Temperature -20-75ºC  
Size 32 x 24 x 7mm can be customized

Precautions:

The pyroelectric infrared sensor should be 2.0-2.2 meters away from the ground. Keep away from air conditioners, refrigerators, stoves and other sensitive places where air temperature changes.
There must be no screens, furniture, large bonsai or other partitions within the detection range.
The pyroelectric infrared sensor should not be directly facing the window, otherwise the interference of hot air currents outside the window and the movement of people will cause false alarms. It is better to have the curtains on conditional conditions. Infrared pyroelectric sensors should also not be installed where there is strong airflow.
The sensitivity of the pyroelectric infrared sensor to the human body is also related to the direction of human motion. Pyroelectric infrared sensors are the least sensitive to radial shift reactions, and are most sensitive to moving sides in the cross-cut direction (ie, the direction perpendicular to the radius). Selecting the proper installation location at the site is to avoid false alarms from the infrared probe and to obtain the best detection sensitivity.


 External Schematic
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector

 Instructions for use:

1. The induction module has an initialization time of about one minute after power-on. During this period, the module will output 0-3 times at intervals, and enter the standby state after one minute.

2. Try to avoid the interference of lights and other interference sources on the lens of the module surface at close range, so as to avoid the introduction of interference signals to cause misoperation; the use environment should try to avoid flowing wind, which will also cause interference to the sensor.

3. The sensor module adopts dual element probe, the window of the probe is rectangular, and the dual element (A element and B element) is located at both ends in the longer direction. When the human body walks from left to right or from right to left, the infrared spectrum reaches the dual element There is a difference in time and distance. The larger the difference, the more sensitive the induction. When the human body walks from the front to the probe or from top to bottom or from bottom to top, the dual element cannot detect the change of the infrared spectrum distance, there is no difference, so the induction is not sensitive or does not work.

4. Adjust the distance to turn the potentiometer clockwise, the sensing distance increases (about 7 meters), otherwise, the sensing distance decreases (about 3 meters).

Adjust the delay potentiometer to rotate clockwise, the induction delay will increase (about 300S), otherwise, the induction delay will decrease (about 5S).
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector

Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector

Pyroelectric Infrared Sensor Module Hw-Sr50 Human Body Motion Detector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier